home *** CD-ROM | disk | FTP | other *** search
/ NetNews Offline 2 / NetNews Offline Volume 2.iso / news / comp / sys / amiga / hardware-part1 / 4685 < prev    next >
Encoding:
Internet Message Format  |  1996-08-05  |  1.4 KB

  1. Path: newshub.cts.com!usenet
  2. From: pwright@crash.cts.com (Phil Wright)
  3. Newsgroups: comp.sys.amiga.hardware
  4. Subject: Re: CyberSCSI UnitControl V1.5
  5. Date: 22 Feb 1996 02:50:39 GMT
  6. Organization: CTS Network Services
  7. Message-ID: <1112.6625T1006T2519@crash.cts.com>
  8. References: <662.6625T1090T1907@inf.fu-berlin.de>
  9. NNTP-Posting-Host: gargoyle.cts.com
  10.  
  11. On 22-Feb-96 01:38:34, rebensto was reported to have said:
  12. >When I set 10MB/s in the special menu of the prg unitcontrol v1.5
  13. >which is shipped with the cyberSCSI controller, my baracuda fast-scsi
  14. >drive is about 7mb/s fast and works without errors. I click on the
  15. >set-button to save these settings it works until I boot again but
  16. >afterwards it always shows a different value there like 7mb/s etc and the
  17. >drive is much slower (about 4- 5mb/s). I use the cyberSCSI with a
  18.  
  19. >How can I set the value to be saved ?
  20.  
  21. You can't.
  22.  
  23. >Or how can I run the program from cli to set the 10Mb/s value
  24. >automatically? It doesn`t seem to be saved in rdb!
  25.  
  26. It isn't.  These settings are negotiated between the drive and the
  27. controller during bootup.  You can put the unitcontrol command into your
  28. user-startup to get the desired settings.
  29.  
  30.   ie. UnitControl UNIT 0 PERIOD 10 OFFSET 12
  31.  
  32. To get SCSI ID 0 set to 10MB/sec synchronous with an offset of 12.  You can
  33. play around with the offset value at higher numbers but you will want to
  34. do a speed test with each setting to find the one you want.
  35.  
  36.   Phil
  37.  
  38. pwright@crash.cts.com
  39.  
  40.